// // BP3.h // testShareCommunication // // Created by zhiwei jing on 13-10-22. // Copyright (c) 2013年 my. All rights reserved. // #import #import "BPDevice.h" #import /** BP3 device class */ @interface BP3 : BPDevice /** * Query battery remaining energy * @param energyValue A block to return the device battery remaining energy percentage, ‘80’ stands for 80%. * @param error A block to return the error in ‘Establish measurement connection’. */ -(void)commandEnergy:(BlockEnergyValue)energyValue errorBlock:(BlockError)error; /** * Establish measurement connection and start BP measurement * @Notice By the first time of new user register via SDK, ‘iHealth disclaimer’ will pop up automatically, and require the user agrees to continue. SDK application requires Internet connection; there is 10-day tryout if SDK cannot connect Internet, SDK is fully functional during tryout period, but will be terminated without verification through Internet after 10 days. * @param blockZeroState Zeroing state * @param pressure Pressure value in the process of measurement, the unit is ‘mmHg’. * @param blockWaveletWithHeartbeat Wavelet data set with heart beat. * @param blockWaveletWithoutHeartbeat Wavelet data set without heart beat. * @param result result of the measurement, including systolic pressure, diastolic pressure, pulse rate and irregular judgment. Relevant key: time, sys, dia, heartRate, irregular * @param error error codes. * Specification: * 1. BPError0 = 0: Unable to take measurements due to arm/wrist movements. * 2. BPError1: Failed to detect systolic pressure. * 3. BPError2: Failed to detect diastolic pressure. * 4. BPError3: Pneumatic system blocked or cuff is too tight during inflation. * 5. BPError4: Pneumatic system leakage or cuff is too loose during inflation. * 6. BPError5: Cuff pressure reached over 300mmHg. * 7. BPError6: Cuff pressure reached over 15 mmHg for more than 160 seconds. * 8. BPError7: Data retrieving error. * 9. BPError8: Data retrieving error. * 10. BPError9: Data retrieving error. * 11. BPError10: Data retrieving error. * 12. BPError11: Communication Error. * 13. BPError12: Communication Error. * 14. BPError13: Low battery. * 15. BPError14: Device bluetooth set failed. * 16. BPError15: Systolic exceeds 260mmHg or diastolic exceeds 199mmHg. * 17. BPError16: Systolic below 60mmHg or diastolic below 40mmHg. * 18. BPError17: Arm/wrist movement beyond range. * 19. BPNormalError=30: device error, error message displayed automatically. * 20. BPOverTimeError: Abnormal communication. * 21. BPNoRespondError: Abnormal communication. * 22. BPBeyondRangeError: device is out of communication range. * 23. BPDidDisconnect: device is disconnected. * 24. BPAskToStopMeasure: measurement has been stopped. * 25. BPInputParameterError=400: Parameter input error. */ -(void)commandStartMeasureWithZeroingState:(BlockZero)blockZeroState pressure:(BlockPressure)pressure waveletWithHeartbeat:(BlockWavelet)blockWaveletWithHeartbeat waveletWithoutHeartbeat:(BlockWavelet)blockWaveletWithoutHeartbeat result:(BlockMeasureResult)result errorBlock:(BlockError)error; /** * Measurement termination and stop upper-arm BPM measurement * @param result The block return ‘YES’ means measurement has been terminated, return ‘NO’ means termination failed. * @param error A block to return the error in ‘Establish measurement connection' in BP3. */ -(void)stopBPMeassure:(BlockResult)result ErrorBlock:(BlockError)error; /** * Disconnect BP3 and delete the measurement port */ -(void)deleteMeasurePort; @end