// // BP5SRW.h // testShareCommunication // // Created by my on 14/10/13. // Copyright (c) 2013年 my. All rights reserved. // #import #import "BPDevice.h" #import /** BP5SRW device class */ @interface BP5SRW : BPDevice /** * Establish measurement connection and start BP measurement. * @Notice By the first time of new user register via SDK, ‘iHealth disclaimer’ will pop up automatically, and require the user agrees to continue. SDK application requires Internet connection; there is 10-day tryout if SDK cannot connect Internet, SDK is fully functional during tryout period, but will be terminated without verification through Internet after 10 days. * @param blockZeroState Zeroing state * @param pressure Pressure value in the process of measurement, the unit is ‘mmHg’. * @param blockWaveletWithHeartbeat Wavelet data set with heart beat. * @param blockWaveletWithoutHeartbeat Wavelet data set without heart beat. * @param result result of the measurement, including systolic pressure, diastolic pressure, pulse rate and irregular judgment. Relevant key: time, sys, dia, heartRate, irregular. * @param redWave A block to return wave information,include the packets order number(0~255),the current measure status(@1 means measuring,@2 means constant Pressure measuring,@3 means completed),the pressure data type(@1 means pressure data ,@2 means wave data) ,the pressure or wave count ,the pressure or wave data array.The corresponding keys are @"packetOrderID",@"measureStatusID",@"pressureDataType",@"pressureCount",@"pressureArray". * @param error Return error codes. * Specification: * 1. BPError0 = 0: Unable to take measurements due to arm/wrist movements. * 2. BPError1: Failed to detect systolic pressure. * 3. BPError2: Failed to detect diastolic pressure. * 4. BPError3: Pneumatic system blocked or cuff is too tight during inflation. * 5. BPError4: Pneumatic system leakage or cuff is too loose during inflation. * 6. BPError5: Cuff pressure reached over 300mmHg. * 7. BPError6: Cuff pressure reached over 15 mmHg for more than 160 seconds. * 8. BPError7: Data retrieving error. * 9. BPError8: Data retrieving error. * 10. BPError9: Data retrieving error. * 11. BPError10: Data retrieving error. * 12. BPError11: Communication Error. * 13. BPError12: Communication Error. * 14. BPError13: Low battery. * 15. BPError14: Device bluetooth set failed. * 16. BPError15: Systolic exceeds 260mmHg or diastolic exceeds 199mmHg. * 17. BPError16: Systolic below 60mmHg or diastolic below 40mmHg. * 18. BPError17: Arm/wrist movement beyond range. * 19. BPError18: Bleed to specified pressure over time * 20. BPError19: Constant pressure acquisition process changes over the specified range of pressure. * 21. BPNormalError=30: device error, error message displayed automatically. * 22. BPOverTimeError: Abnormal communication. * 23. BPNoRespondError: Abnormal communication. * 24. BPBeyondRangeError: device is out of communication range. * 25. BPDidDisconnect: device is disconnected. * 26. BPAskToStopMeasure: measurement has been stopped. * 27. BPInputParameterError=400: Parameter input error. */ -(void)commandStartMeasureWithZeroingState:(BlockZero)blockZeroState pressure:(BlockPressure)pressure waveletWithHeartbeat:(BlockWavelet)blockWaveletWithHeartbeat waveletWithoutHeartbeat:(BlockWavelet)blockWaveletWithoutHeartbeat result:(BlockMeasureResult)result redWave:(BlockRedWaveDic)redWave errorBlock:(BlockError)error; /** * Measurement termination and stop BP5SRW measurement * @param success The block return means measurement has been terminated. * @param error A block to return the error in ‘Establish measurement connection’ in BP5SRW. */ -(void)stopBPMeassureSuccessBlock:(BlockSuccess)success errorBlock:(BlockError)error; /** * Synchronize time and judge if the device supports BT auto-connection, offline detection, and if the function on or off, corresponding KEY as haveBlue, haveOffline, blueOpen, offlineOpen. ‘True’ means yes or on, ‘False’ means no or off * @param function A block to return the function and states that the device supports. * @param error A block to refer ‘error’ in ‘Establish measurement connection’ in BP5SRW. */ -(void)commandFunction:(BlockDeviceFunction)function errorBlock:(BlockError)error; /** * Query battery remaining energy * @param energyValue A block to return the device battery remaining energy percentage, ‘80’ stands for 80%. * @param error A block to return the error in ‘Establish measurement connection’. */ -(void)commandEnergy:(BlockEnergyValue)energyValue errorBlock:(BlockError)error; /** Set the target measure configure @param targetPressure Set the target constant pressure in measuring. @param fluctuationPressure Set the allowed range of pressure fluctuations. @param sampleTime Set the pressure sample time. @param setResult Success callback @param error A block to return the error in ‘Establish measurement connection’. */ -(void)CommandSetPressureSamplewithTargetPressure:(NSNumber *)targetPressure fluctuationRange:(NSNumber *)fluctuationPressure sampleTime:(NSNumber *)sampleTime disposeSetPresureTargetSuccess:(BlockSuccess)setResult errorBlock:(BlockError)error; /** * Disconnect current device */ -(void)commandDisconnectDevice; @end