// BP5SRW.h
// testShareCommunication
//
// Created by my on 14/10/13.
// Copyright (c) 2013年 my. All rights reserved.
//
#import <Foundation/Foundation.h>
#import "BPDevice.h"
#import <UIKit/UIKit.h>
/**
BP5SRW device class
*/
@interface BP5SRW : BPDevice
/**
* Establish measurement connection and start BP measurement.
* @Notice By the first time of new user register via SDK, ‘iHealth disclaimer’ will pop up automatically, and require the user agrees to continue. SDK application requires Internet connection; there is 10-day tryout if SDK cannot connect Internet, SDK is fully functional during tryout period, but will be terminated without verification through Internet after 10 days.
* @param blockZeroState Zeroing state
* @param pressure Pressure value in the process of measurement, the unit is ‘mmHg’.
* @param blockWaveletWithHeartbeat Wavelet data set with heart beat.
* @param blockWaveletWithoutHeartbeat Wavelet data set without heart beat.
* @param result result of the measurement, including systolic pressure, diastolic pressure, pulse rate and irregular judgment. Relevant key: time, sys, dia, heartRate, irregular.
* @param redWave A block to return wave information,include the packets order number(0~255),the current measure status(@1 means measuring,@2 means constant Pressure measuring,@3 means completed),the pressure data type(@1 means pressure data ,@2 means wave data) ,the pressure or wave count ,the pressure or wave data array.The corresponding keys are @"packetOrderID",@"measureStatusID",@"pressureDataType",@"pressureCount",@"pressureArray".
* @param error Return error codes.
* Specification:
* 1. BPError0 = 0: Unable to take measurements due to arm/wrist movements.
* 2. BPError1: Failed to detect systolic pressure.
* 3. BPError2: Failed to detect diastolic pressure.
* 4. BPError3: Pneumatic system blocked or cuff is too tight during inflation.
* 5. BPError4: Pneumatic system leakage or cuff is too loose during inflation.
* 6. BPError5: Cuff pressure reached over 300mmHg.
* 7. BPError6: Cuff pressure reached over 15 mmHg for more than 160 seconds.
* 8. BPError7: Data retrieving error.
* 9. BPError8: Data retrieving error.
* 10. BPError9: Data retrieving error.
* 11. BPError10: Data retrieving error.
* 12. BPError11: Communication Error.
* 13. BPError12: Communication Error.
* 14. BPError13: Low battery.
* 15. BPError14: Device bluetooth set failed.
* 16. BPError15: Systolic exceeds 260mmHg or diastolic exceeds 199mmHg.
* 17. BPError16: Systolic below 60mmHg or diastolic below 40mmHg.
* 18. BPError17: Arm/wrist movement beyond range.
* 19. BPError18: Bleed to specified pressure over time
* 20. BPError19: Constant pressure acquisition process changes over the specified range of pressure.
* 21. BPNormalError=30: device error, error message displayed automatically.
* 22. BPOverTimeError: Abnormal communication.
* 23. BPNoRespondError: Abnormal communication.
* 24. BPBeyondRangeError: device is out of communication range.
* 25. BPDidDisconnect: device is disconnected.
* 26. BPAskToStopMeasure: measurement has been stopped.
* 27. BPInputParameterError=400: Parameter input error.
*/
-(void)commandStartMeasureWithZeroingState:(BlockZero)blockZeroState pressure:(BlockPressure)pressure waveletWithHeartbeat:(BlockWavelet)blockWaveletWithHeartbeat waveletWithoutHeartbeat:(BlockWavelet)blockWaveletWithoutHeartbeat result:(BlockMeasureResult)result redWave:(BlockRedWaveDic)redWave errorBlock:(BlockError)error;
/**
* Measurement termination and stop BP5SRW measurement
* @param success The block return means measurement has been terminated.
* @param error A block to return the error in ‘Establish measurement connection’ in BP5SRW.
*/
-(void)stopBPMeassureSuccessBlock:(BlockSuccess)success errorBlock:(BlockError)error;
/**
* Synchronize time and judge if the device supports BT auto-connection, offline detection, and if the function on or off, corresponding KEY as haveBlue, haveOffline, blueOpen, offlineOpen. ‘True’ means yes or on, ‘False’ means no or off
* @param function A block to return the function and states that the device supports.
* @param error A block to refer ‘error’ in ‘Establish measurement connection’ in BP5SRW.
*/
-(void)commandFunction:(BlockDeviceFunction)function errorBlock:(BlockError)error;
/**
* Query battery remaining energy
* @param energyValue A block to return the device battery remaining energy percentage, ‘80’ stands for 80%.
* @param error A block to return the error in ‘Establish measurement connection’.
*/
-(void)commandEnergy:(BlockEnergyValue)energyValue errorBlock:(BlockError)error;
/**
Set the target measure configure
@param targetPressure Set the target constant pressure in measuring.
@param fluctuationPressure Set the allowed range of pressure fluctuations.
@param sampleTime Set the pressure sample time.
@param setResult Success callback
@param error A block to return the error in ‘Establish measurement connection’.
*/
-(void)CommandSetPressureSamplewithTargetPressure:(NSNumber *)targetPressure fluctuationRange:(NSNumber *)fluctuationPressure sampleTime:(NSNumber *)sampleTime disposeSetPresureTargetSuccess:(BlockSuccess)setResult errorBlock:(BlockError)error;
/**
* Disconnect current device
*/
-(void)commandDisconnectDevice;
@end
|